ABYC Marine DC Wire Ampacity & Sizing Chart
Engineered according to ABYC Standard E-11 for single conductors rated at 105°C insulation in marine environments.
Prefer automatic calculations?
Plug in your amps and wire distance to get the exact safe AWG instantly.
| Wire Gauge (AWG) | Circular Mils (CM) | Ohms / 1,000 ft | Max Amps (Outside Engine Room) | Max Amps (Inside Engine Room 50°C) |
|---|---|---|---|---|
| 16 AWG | 2,580 | 4.99 Ω | 25 A | 21 A |
| 14 AWG | 4,110 | 3.07 Ω | 35 A | 30 A |
| 12 AWG | 6,530 | 1.93 Ω | 45 A | 38 A |
| 10 AWG | 10,380 | 1.21 Ω | 60 A | 51 A |
| 8 AWG | 16,510 | 0.764 Ω | 80 A | 68 A |
| 6 AWG | 26,240 | 0.481 Ω | 120 A | 102 A |
| 4 AWG | 41,740 | 0.302 Ω | 160 A | 136 A |
| 2 AWG | 66,360 | 0.190 Ω | 210 A | 178 A |
| 1/0 AWG | 105,600 | 0.120 Ω | 285 A | 242 A |
| 2/0 AWG | 133,100 | 0.095 Ω | 330 A | 280 A |